• DocumentCode
    1487480
  • Title

    Noninvasive Estimation of the Electrohysterographic Action-Potential Conduction Velocity

  • Author

    Rabotti, Chiara ; Mischi, Massimo ; Oei, S. Guid ; Bergmans, Jan W M

  • Author_Institution
    Dept. of Electr. Eng., Eindhoven Univ. of Technol., Eindhoven, Netherlands
  • Volume
    57
  • Issue
    9
  • fYear
    2010
  • Firstpage
    2178
  • Lastpage
    2187
  • Abstract
    Electrophysiological monitoring of the fetal-heart and the uterine-muscle activity, referred to as an electrohysterogram, is essential to permit timely treatment during pregnancy. While remarkable progress is reported for fetal-cardiac-activity monitoring, the electrohysterographic (EHG) measurement and interpretation remain challenging. In particular, little attention has been paid to the analysis of the EHG propagation, whose characteristics might be predictive of the preterm delivery. Therefore, this paper focuses, for the first time, on the noninvasive estimation of the conduction velocity of the EHG-action potentials. To this end, multichannel EHG recording and surface high-density electrodes are used. A maximum-likelihood method is employed for analyzing the EHG-action-potential propagation in two dimensions. The use of different weighting strategies of the derived cost function is introduced to deal with the poor signal similarity between different channels. The presented methods were evaluated by specific simulations proving the best weighting strategy to lead to an accuracy improvement of 56.7%. EHG measurements on ten women with uterine contractions confirmed the feasibility of the method by leading to conduction velocity values within the expected physiological range.
  • Keywords
    bioelectric potentials; biomedical electrodes; biomedical measurement; cardiology; electromyography; maximum likelihood estimation; muscle; obstetrics; patient monitoring; EHG propagation; action-potential conduction velocity; electrohysterography; electrophysiological monitoring; fetal-heart activity; maximum-likelihood method; multichannel EHG recording; noninvasive estimation; surface high-density electrodes; uterine contractions; uterine-muscle activity; Action potentials (APs); conduction velocity (CV); electrohysterography (EHG); electromyography; high density electrodes; maximum likelihood (ML) estimation; Action Potentials; Electromyography; Female; Fetal Monitoring; Humans; Neural Conduction; Pregnancy; Signal Processing, Computer-Assisted; Uterine Contraction;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2010.2049111
  • Filename
    5462870