DocumentCode :
148781
Title :
Creep corrosion test in flowers of sulfur chamber
Author :
Fu, Hui ; Singh, Prashant ; Jing Zhang
Author_Institution :
Int. Electron. Manuf. Initiative, Shanghai, China
fYear :
2014
fDate :
23-25 April 2014
Firstpage :
197
Lastpage :
201
Abstract :
Creep corrosion is the corrosion of the copper (and sometimes silver) metallization on PCBs and the creeping of the corrosion product (mostly sulfides of copper and sometimes silver) on the board surfaces which may lead to the electrically shorting of neighboring features on PCBs. The problem of creep corrosion has been largely brought under control by selecting finishes, by trial and error, that have less propensity to creep corrosion. But the challenge of a reliable qualification test for creep corrosion remains, though some progress has been made developing the mixed flowing gas (MFG), the Chavant clay and the flowers of sulfur tests. The iNEMI (International Electronics Manufacturing Initiative) technical project team on creep corrosion is developing a flowers-of-sulfur (FOS) based qualification test for creep corrosion on printed-circuit boards (PCBs). The test setup consists of a 300-mm cube chamber with two means of mounting the test specimens and flowing air over them to expose them to constant, predefined humidity and temperature conditions and sulfur and other contaminants. The FOS chamber performance has been evaluated using copper and silver foils and preliminary test runs have been conducted on PCBs from a manufacturing lot known to have failed in service. The effect of air velocity on the copper and silver corrosion rates was quite linear. The effect of humidity on copper and silver corrosion rates in the low air velocity range of less than 0.1 m/s showed a strong dependence on relative humidity. In the high velocity range of 1 m/s, there was no clear dependence of humidity on copper and silver corrosion rates. A means has been developed for applying controlled concentration of ionic contamination on selected local areas of test PCBs. Preliminary test runs have shown that ionic contamination found in fine dust may be a necessary condition for copper creep corrosion. The focus of this paper is the design of a FOS chamber and its performance evaluation - sing copper and silver foils and the preliminary testing of the procedure using PCBs from a manufacturing lot known to have failed in service.
Keywords :
circuit reliability; contamination; copper alloys; corrosion testing; creep testing; metallisation; printed circuit testing; silver alloys; sulphur; Ag; Cu; FOS based qualification test; FOS chamber performance; International Electronics Manufacturing Initiative; MFG; PCBs; S; air velocity effect; board surfaces; contaminants; copper corrosion rates; copper creep corrosion; copper foils; copper metallization; corrosion product; creep corrosion test; cube chamber; flowers-of-sulfur; flowing air; humidity conditions; iNEMI; ionic contamination concentration; mixed flowing gas; performance evaluation; printed-circuit boards; relative humidity; reliable qualification test; silver corrosion rates; silver foils; size 300 mm; sulfur chamber; temperature conditions; Contamination; Copper; Corrosion; Creep; Humidity; Qualifications; Silver; creep corrosion; fine dust; flower of sulfer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronics Packaging (ICEP), 2014 International Conference on
Conference_Location :
Toyama
Print_ISBN :
978-4-904090-10-7
Type :
conf
DOI :
10.1109/ICEP.2014.6826688
Filename :
6826688
Link To Document :