• DocumentCode
    148837
  • Title

    Characterization of tactile display for stiffness distribution using Magneto-rheological fluid

  • Author

    Ishizuka, Hirokazu ; Lorenzoni, Nicolo ; Miki, Nobuhiko

  • Author_Institution
    Dept. of Mech. Eng., Keio Univ., Yokohama, Japan
  • fYear
    2014
  • fDate
    23-25 April 2014
  • Firstpage
    400
  • Lastpage
    404
  • Abstract
    This paper demonstrates a tactile display to reproduce stiffness distribution using a Magneto-rheological (MR) fluid. Computed tomography (CT) scan and endoscope are widely used to diagnosis intravital condition and contribute the quality of life. However, CT scan cannot detect tumors smaller than 5 mm and endoscope can only diagnosis only surface of the tissue surface. Since tumors is stiffer than normal tissue, intravital palpation may be effective to detect tumors smaller than 5 mm. To perform intravital palpation, tactile displays to reproduce stiffness information from micro tactile sensors is needed. In present study, we propose tactile display using MR fluid to change its stiffness in an external magnetic field. MR fluid was encapsulated in an acrylic chamber covered by a thin PDMS membrane. Compression tests were conducted to evaluate mechanical properties of the display. Two types of probes were used. A narrow probe was used to perform detailed measurement and a wider probe was used to simulate how subjects felt. The experimental results indicated that the display could successfully create the stiffness of tumor under an external magnetic field of 200 mT. Then, the display was evaluated using five subjects. The results indicated all of the subjects perceived stiffer spot smaller than 5 mm under an external magnetic field of 100 mT.
  • Keywords
    biomembranes; compressive testing; computerised tomography; endoscopes; magnetic fields; magnetorheology; microsensors; tactile sensors; tumours; CT scan; acrylic chamber; compression tests; computed tomography scan; diagnosis intravital condition; endoscope; external magnetic field; intravital palpation; magneto-rheological fluid; mechanical properties; microtactile sensors; stiffness distribution; tactile display; thin PDMS membrane; tissue surface; tumors; Fluids; Magnetic field measurement; Magnetic liquids; Magnetic separation; Probes; Tumors; Liquid encapsulation; MR fluid; Smart fluid; Tactile display;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronics Packaging (ICEP), 2014 International Conference on
  • Conference_Location
    Toyama
  • Print_ISBN
    978-4-904090-10-7
  • Type

    conf

  • DOI
    10.1109/ICEP.2014.6826717
  • Filename
    6826717