Investigations of a Double-Gap Vircator at Submicrosecond Pulse Durations
Author :
Shlapakovski, Anatoli S. ; Queller, Tal ; Bliokh, Yuri P. ; Krasik, Yakov E.
Author_Institution :
Dept. of Phys., Technion - Israel Inst. of Technol., Haifa, Israel
Volume :
40
Issue :
6
fYear :
2012
fDate :
6/1/2012 12:00:00 AM
Firstpage :
1607
Lastpage :
1617
Abstract :
The results of investigations of a double-gap vircator driven by a 20 Ω and 500-ns generator operating in the output voltage range 400-600 kV are presented. The vircator generated microwave pulses with a peak power of up to 200 MW at ~5% efficiency and the frequency varied from 2.0 to 2.3 GHz depending on the cavity geometry. The limitations on the microwave pulse duration not related to the cathode plasma expansion are addressed. On the one hand, the microwave generation is terminated because of the plasma formation at the foil separating the cavity sections, so that the virtual cathode (VC) electron space charge is neutralized by the plasma ion flux. On the other hand, if the electron beam energy deposition into the foil is reduced, a substantial delay in the start time of the microwave generation appears, which has been studied in detail. With these limiting factors, the microwave pulse full duration varied from 100 to 350 ns; the maximal full width at half maximum duration achieved in the experiments was ~180 ns. Measurements of the current transmitted through the vircator cavity indicated the existence of a VC in spite of the absence of microwave generation during the delay. The experimental dependence of the microwave generation starting current on the diode voltage is presented, and possible mechanisms behind the generation delay are discussed. Simplified numerical simulations emphasize the role of the portion of electrons that are reflected from the VC, the number of which must be sufficient for the microwave generation to occur.
Keywords :
cathodes; electron beam deposition; microwave generation; numerical analysis; plasma devices; pulse generators; vircators; VC electron space charge; cavity geometry; cavity section; current 20 A; diode voltage; double-gap vircator; electron beam energy deposition; foil; frequency 2 GHz to 2.3 GHz; generation delay; generator; microwave generation; microwave pulse duration; numerical simulation; output voltage; plasma formation; plasma ion flux; submicrosecond pulse duration; time 100 ns to 350 ns; time 500 ns; vircator cavity; virtual cathode; voltage 400 kV to 600 kV; Acceleration; Cathodes; Cavity resonators; Delay; Microwave generation; Plasmas; Radio frequency; High-power microwaves; microwave pulse shortening; vircators;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.2012.2190104
Filename :
6179551
Link To Document :
بازگشت