DocumentCode :
1488509
Title :
Response of thermal demand meters
Author :
Nelson, J. S.
Author_Institution :
General Electric Company, West Lynn, Mass.
Volume :
68
Issue :
12
fYear :
1949
Firstpage :
1046
Lastpage :
1046
Abstract :
THE TIME OF RESPONSE of demand meters is of critical importance wherever a demand charge is made for electricity. In demand meters of the mechanical block-interval type the demand interval is usually governed by a gear train and resetting mechanism connected with some synchronous device, such as a clock motor, and response time presents no special problems in design. The response time of thermal meters depends upon less easily evaluated constants and coefficients. This article examines these factors and presents equations from which the time of response may be calculated.
Keywords :
Equations; Heating; Instruments; Mathematical model; Spirals; Thermal conductivity; Time factors;
fLanguage :
English
Journal_Title :
Electrical Engineering
Publisher :
ieee
ISSN :
0095-9197
Type :
jour
DOI :
10.1109/EE.1949.6443275
Filename :
6443275
Link To Document :