• DocumentCode
    1494794
  • Title

    A High-Sensitivity Small-Animal PET Scanner: Development and Initial Performance Measurements

  • Author

    Kao, Chien-Min ; Xie, Qingguo ; Dong, Yun ; Wan, Lu ; Chen, Chin-Tu

  • Author_Institution
    Dept. of Radiol., Univ. of Chicago, Chicago, IL, USA
  • Volume
    56
  • Issue
    5
  • fYear
    2009
  • Firstpage
    2678
  • Lastpage
    2688
  • Abstract
    An important challenge in positron emission tomography (PET) is the development of dedicated small-animal PET (muPET) systems having high sensitivity. In this paper, we investigate the use of an opposing pair of large-area detectors having high detection efficiency and moderate depth-of-interaction resolution in a compact scanner geometry for achieving a high system sensitivity. Substantial resolution degradations created by this hardware configuration, on the other hand, are corrected for by applying model-based image reconstruction. We have developed a prototype scanner adopting this design and evaluated its performance properties. Our results show that the prototype can achieve a central sensitivity of ~28.2% when using an energy window (EW) of 250-750 keV and a coincidence time window (CW) of 10 ns. When decreasing the EW to 400-750 keV, the central sensitivity still remains high at ~14.4%. Over the typical ranges of radioactivity used in PET rodent imaging with [18F]fluorodeoxyglucose (FDG), the prototype provides noise-equivalent count rates (NECRs) that are considerably higher than other muPET systems. For a mouse/rat-sized cylinder, we obtain a peak NECR of ~ 1.86/1.2 Mcps at ~32/40 MBq when using a 250/350-750 keV EW and a 6 ns CW. Using a resolution phantom, we obtain an average FWHM (full width at the half-maximum) of 1.79 mm for 1.35 mm-diameter rod sources when the axis of the phantom is vertical to the detectors of the prototype. This is consistent with the 1.2 mm FWHM image resolution previously obtained by using simulation data. The prototype also generates FDG rat images having good visual quality.
  • Keywords
    biomedical imaging; image reconstruction; phantoms; positron emission tomography; solid scintillation detectors; FDG; FDG rat images; LYSO; NECR; coincidence time window; compact scanner geometry; dense scintillators crystals; depth-of-interaction resolution; electron volt energy 250 keV to 750 keV; fluorodeoxyglucose; hardware configuration; high detection efficiency; image reconstruction; large-area detectors; noise-equivalent count rates; phantom; positron emission tomography; radioactivity; small-animal PET scanner; Degradation; Detectors; Energy resolution; Geometry; Hardware; Image resolution; Imaging phantoms; Measurement; Positron emission tomography; Prototypes; High-sensitivity PET; positron emission tomography (PET); small-animal PET;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2009.2026647
  • Filename
    5280543