DocumentCode :
1496361
Title :
Dummy loads for large industrial welders
Author :
Brown, A. W. ; Johnson, S. E.
Author_Institution :
Illinois Northern Utilities Company, Dixon, Ill.
Volume :
68
Issue :
1
fYear :
1949
Firstpage :
12
Lastpage :
14
Abstract :
A solution to the problem of objectionable voltage fluctuation in large industrial welders can be brought about by electronically interlocking each single phase welder with a dummy load to fill in the period of no load between welds; the load to be of suitable magnitude to keep the voltage variation within allowable limits. In addition, this method also results in considerable reduction in kilowatt-hour consumption of ballast load.
Keywords :
Capacitors; Electronic ballasts; Fluctuations; Materials; Reactive power; Voltage fluctuations; Welding;