DocumentCode
1496968
Title
Study on Firing Conditions of Multigap Gas Switch for Fast Linear Transformer Driver
Author
Liu, Xuandong ; Sun, Fengju ; Liang, Tianxue ; Jiang, Xiaofeng ; Zhang, Qiaogen ; Qiu, Aici
Author_Institution
Key Lab. of Electr. Insulation & Power Equip., Xi´´an Jiaotong Univ., Xi´´an, China
Volume
38
Issue
7
fYear
2010
fDate
7/1/2010 12:00:00 AM
Firstpage
1670
Lastpage
1674
Abstract
As one of the critical elements of fast linear transformer driver (FLTD), gas switch directly influences the output parameters, stability, and reliability of generators based on FLTD technology. In this paper, a multigap gas switch with six gaps in series has been investigated to study the proper firing conditions to get better performance for FLTD. The self-breakdown voltage with different gas pressure has been studied to derive the working ratio of the switch. The triggered breakdown delay and jitter with different charge voltage, gas pressure, and working ratio have been studied. The results indicate that when the switch is triggered by a 100-kV trigger voltage pulse under 180-kV charge voltage and 0.325-MPa pure nitrogen (70% working ratio), the delay time and the jitter are 34 and 1 ns, respectively.
Keywords
driver circuits; jitter; power transformers; pulse generators; pulsed power switches; FLTD technology; breakdown delay; fast linear transformer driver; firing conditions; gas pressure; generators reliability; jitter; multigap gas switch; pressure 0.325 MPa; self-breakdown voltage; voltage 100 kV; voltage 180 kV; Delay time; fast linear transformer driver (FLTD); gas switch; jitter; multigap;
fLanguage
English
Journal_Title
Plasma Science, IEEE Transactions on
Publisher
ieee
ISSN
0093-3813
Type
jour
DOI
10.1109/TPS.2010.2048762
Filename
5467190
Link To Document