    The authors present AC loss measurements for a series of wires in which the proximity effect has been greatly reduced by increasing the distance between the filaments while retaining high values of the overall critical current density, typically 3000 A/mm2 at 0.5 T. For the best performing wires, 50-Hz AC losses in W/(Am) (=(losses in W/m3)/(overall Jc in A/m2)) for small test coils are a factor of ten lower for 0.5-T peak field and a factor of three lower at 1-T peak field. For wires with negligible proximity coupling, losses at low fields are reduced compared to that calculated by the Bean model, due to the small number of flux lines that thread across the width of each filament
  • Keywords
    composite superconductors; critical current density (superconductivity); flux flow; magnetic leakage; niobium alloys; proximity effect; titanium alloys; type II superconductors; AC loss measurements; Bean model; NbTi ultrafine multifilamentary wires; critical current density; flux lines; magnetisation losses; proximity effect; test coils; Critical current density; Current measurement; Density measurement; Loss measurement; Niobium compounds; Performance evaluation; Proximity effect; Testing; Titanium compounds; Wires;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.92688
  • Filename
    92688