• DocumentCode
    1499008
  • Title

    Characterization and Experimental Results of a Novel Sensor for Measuring the Contact Force From Myenteric Contractions

  • Author

    Terry, Benjamin S. ; Schoen, Jonathan A. ; Rentschler, Mark E.

  • Author_Institution
    Univ. of Colorado, Boulder, CO, USA
  • Volume
    59
  • Issue
    7
  • fYear
    2012
  • fDate
    7/1/2012 12:00:00 AM
  • Firstpage
    1971
  • Lastpage
    1977
  • Abstract
    The intraluminal pressures and traction forces associated with the migrating motor complex are well understood; however, the contact forces directly exerted by the bowel wall on a solid, or near solid, bolus have not previously been measured. Quantifying contact forces is an important component to understanding the net force experienced by an in vivo robotic capsule endoscope. In this paper, we develop a novel sensor, the migrating motor complex force sensor (MFS), for measuring the contact force generated by the contracting myenteron of the small intestine. The MFS consists of a perfused manometer connected to four torus-shaped balloons custom formed of natural latex rubber and embedded with temperature and pressure sensors. Force exerted on the balloon causes sensor pressure change. In vivo, the MFS measures the magnitude and axial location of contact pressure exerted by the myenteron. The device is tested in vivo in a live porcine model on the middle small bowel. The mean total force per centimeter of axial length of intestine that occurred over a 16-min interval in vivo was 1.04 N·cm-1 in the middle region of the small intestine; the measured force is in the range of theoretical values.
  • Keywords
    biological organs; biosensors; force sensors; prosthetics; rubber; MFS; intraluminal pressures; live porcine model; mean total force per centimeter; middle small bowel wall; migrating motor complex force sensor; myenteric contractions; natural latex rubber; robotic capsule endoscope; small intestine; surgical implants; time 16 min; torus-shaped balloon custom; traction forces; Force; In vivo; Pressure measurement; Robot sensing systems; Stress; Temperature measurement; Temperature sensors; Contact force; in vivo; migrating motor complex force sensor (MFS); small intestine; solid bolus; Animals; Biomechanics; Equipment Design; Intestine, Small; Manometry; Myoelectric Complex, Migrating; Reproducibility of Results; Swine; Transducers, Pressure;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2012.2195179
  • Filename
    6186792