• DocumentCode
    1499592
  • Title

    Time-frequency matching of warped depth-EEG seizure observations

  • Author

    Wendling, F. ; Shamsollahi, M.B. ; Badier, J.M. ; Bellanger, J.J.

  • Author_Institution
    Lab. Traitement du Signal et de l´´Image, Rennes I Univ., France
  • Volume
    46
  • Issue
    5
  • fYear
    1999
  • fDate
    5/1/1999 12:00:00 AM
  • Firstpage
    601
  • Lastpage
    605
  • Abstract
    A methodology of comparing depth-EEG seizure recordings is presented. The approach is based on an extension of Wagner and Fischer´s (1974) algorithm to N×2-dimensional sets, allowing a confrontation of nonequal duration observations characterized by their time-frequency distributions. It proceeds by time and frequency warping on the first observation to match the second, under cost constraints. Preliminary results show that relevant signatures can be extracted from recordings.
  • Keywords
    electroencephalography; medical signal processing; time-frequency analysis; N/spl times/2-dimensional sets; Wagner-Fischer algorithm; cost constraints; electrodiagnostics; epilepsy; nonequal duration observations; relevant signatures extraction; time-frequency matching; warped depth-EEG seizure observations; Costs; Data mining; Distributed computing; Electroencephalography; Epilepsy; Labeling; Signal processing algorithms; Surgery; Temporal lobe; Time frequency analysis; Algorithms; Electroencephalography; Epilepsy, Temporal Lobe; Humans; Reproducibility of Results; Signal Processing, Computer-Assisted;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.759060
  • Filename
    759060