DocumentCode
1499592
Title
Time-frequency matching of warped depth-EEG seizure observations
Author
Wendling, F. ; Shamsollahi, M.B. ; Badier, J.M. ; Bellanger, J.J.
Author_Institution
Lab. Traitement du Signal et de l´´Image, Rennes I Univ., France
Volume
46
Issue
5
fYear
1999
fDate
5/1/1999 12:00:00 AM
Firstpage
601
Lastpage
605
Abstract
A methodology of comparing depth-EEG seizure recordings is presented. The approach is based on an extension of Wagner and Fischer´s (1974) algorithm to N×2-dimensional sets, allowing a confrontation of nonequal duration observations characterized by their time-frequency distributions. It proceeds by time and frequency warping on the first observation to match the second, under cost constraints. Preliminary results show that relevant signatures can be extracted from recordings.
Keywords
electroencephalography; medical signal processing; time-frequency analysis; N/spl times/2-dimensional sets; Wagner-Fischer algorithm; cost constraints; electrodiagnostics; epilepsy; nonequal duration observations; relevant signatures extraction; time-frequency matching; warped depth-EEG seizure observations; Costs; Data mining; Distributed computing; Electroencephalography; Epilepsy; Labeling; Signal processing algorithms; Surgery; Temporal lobe; Time frequency analysis; Algorithms; Electroencephalography; Epilepsy, Temporal Lobe; Humans; Reproducibility of Results; Signal Processing, Computer-Assisted;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/10.759060
Filename
759060
Link To Document