DocumentCode :
1503155
Title :
Corona-level scanning of high-voltage power cables
Author :
Gooding, F. H. ; Slade, H. B.
Author_Institution :
The Okonite Company, Passaic, N.J.
Volume :
77
Issue :
3
fYear :
1958
fDate :
3/1/1958 12:00:00 AM
Firstpage :
236
Lastpage :
236
Abstract :
AN APPARATUS has been developed for the purpose of detecting and locating the presence of small voids or air pockets in rubber or plastic cable insulation. This is especially important in cases where the operating voltage of the cable is high enough to ionize the gas in these void spaces, because continued ionization may eventually erode or burn its way through the insulation, and result in cable failure.