Title :
A Wirelessly Powered Electro-Acupuncture Based on Adaptive Pulsewidth Monophase Stimulation
Author :
Kiseok Song ; Long Yan ; Seulki Lee ; Yoo, J. ; Hoi-Jun Yoo
Author_Institution :
Dept. of Electr. Eng., Korea Adv. Inst. of Technol. (KAIST), Daejeon, South Korea
fDate :
4/1/2011 12:00:00 AM
Abstract :
A wirelessly powered electro-acupuncture (EA) system with adaptive-pulsewidth (APW) monophase stimulation is presented for convenient invasive medicine. The proposed system removes cumbersome wires connected between EA nodes and an EA controller in order to realize both patients´ convenience and remedial values simultaneously. An ultra-low-power stimulator integrated circuit (IC) that is integrated on the flexible-printed-circuit board (F-PCB) is attached to the tip of a needle electrode. Combined with a conductive yarn helical antenna wound around the needle electrode, the EA node receives wireless power from the EA controller using 433 MHz with the maximum loss of 6 dB. A zero-Vth nMOS rectifier harvests a supply voltage of 1.0 V from a -16-dBm incoming power signal with 32% efficiency. To deal with a body impedance variation (BIV) in the range of 100-200 kΩ , the proposed APW stimulator IC, fabricated in a 0.18-μm 1P6M complementary metal-oxide semiconductor CMOS process and occupying 1.56 mm2, enables constant charge injection of 80-nC/stimulation. To ensure the patients´ safety, the EA node (a pair of EAs) shares ground and clock wires to operate in alternate monophase (AMP) fashion for neutralizing the injected charge. The proposed wirelessly powered EA node was verified by applying it to a chunk of pork as a body model with the wireless power supplied from an RF signal generator (output power of 10 dBm and located 30 cm away).
Keywords :
CMOS integrated circuits; biomedical electronics; integrated circuit modelling; neuromuscular stimulation; printed circuits; EA controller; EA nodes; adaptive pulsewidth monophase stimulation; alternate monophase; convenient invasive medicine; flexible-printed-circuit board; ultra-low-power stimulator integrated circuit; wirelessly powered electro-acupuncture; Antenna measurements; Antennas; Driver circuits; Electrodes; Integrated circuits; MOS devices; Needles; Adaptive pulsewidth control; alternate monophase stimulation; body impedance variation; conductive yarn helical antenna; electro-acupuncture; industrial-scientific-medical (ISM) band; wirelessly powered stimulator;
Journal_Title :
Biomedical Circuits and Systems, IEEE Transactions on
DOI :
10.1109/TBCAS.2011.2144592