Calibration of test fixtures using at least two standards [microwave circuits]
Author
Silvonen, Kimmo J.
Author_Institution
Helsinki Univ. of Technol., Espoo, Finland
Volume
39
Issue
4
fYear
1991
fDate
4/1/1991 12:00:00 AM
Firstpage
624
Lastpage
630
Abstract
The determination of the error networks in measurements of microwave circuits with arbitrary test fixtures is studied. A general-purpose deembedding method for known standards is shown. Also, a method for symmetrical test fixtures is described. The method uses only two fixture standards, of which one must be a two-port standard with a transmission not equal to zero. A computer simulation is used to compare the error sensitivities of the different calibration algorithms. The main advantage of the methods described is that the standards can be modeled freely and any idealization or restriction to certain special standards is not necessary. Any kind of standard can be used if the S-parameters are known or if a circuit model for the standard can be determined. Also, the dispersion of the microstrip line standards can easily be taken into account
Keywords
S-parameters; calibration; measurement errors; measurement standards; microwave circuits; microwave measurement; test equipment; S-parameters; calibration algorithms; circuit model; computer simulation; deembedding method; dispersion; error networks; error sensitivities; measurements; microstrip circuits; microstrip line standards; microwave circuits; standards; stripline circuits; symmetrical test fixtures; two-port standard; Calibration; Circuit testing; Coaxial components; Distributed parameter circuits; Fixtures; Measurement standards; Microwave circuits; Reflection; Scattering parameters; Transmission line measurements;
fLanguage
English
Journal_Title
Microwave Theory and Techniques, IEEE Transactions on
Publisher
ieee
ISSN
0018-9480
Type
jour
DOI
10.1109/22.76424
Filename
76424
Link To Document