• DocumentCode
    1508468
  • Title

    Folded Floating-Gate CMOS Biosensor for the Detection of Charged Biochemical Molecules

  • Author

    Chen, Baozhen ; Parashar, Archana ; Pandey, Santosh

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Iowa State Univ., Ames, IA, USA
  • Volume
    11
  • Issue
    11
  • fYear
    2011
  • Firstpage
    2906
  • Lastpage
    2910
  • Abstract
    A folded floating-gate CMOS biosensor is realized for the detection of charged biochemical molecules. The biosensor comprises a field-effect transistor with a floating-gate, a control-gate, and a sensing area. Charged biochemical molecules placed on the sensing area induce a voltage on the floating-gate and a relative shift in the threshold characteristics. Compared to conventional devices, the floating-gate here is folded to span the entire device. This allows us to place the sensing area above the field-effect transistor (FET), thus reducing the total device area. The fabricated devices show good sensitivity to the polarity and concentration of charged poly amino acids. Possible applications of the device include electronic detection of spatial and temporal charge migration such as in biological processes.
  • Keywords
    CMOS integrated circuits; biochemistry; biological techniques; biosensors; field effect transistors; molecular biophysics; biological processes; charged biochemical molecule detection; charged poly amino acids; control-gate; field-effect transistor; floating-gate; folded floating-gate CMOS biosensor; temporal charge migration; Arrays; Biosensors; CMOS integrated circuits; FETs; Threshold voltage; Voltage control; Bio-FET; CMOS sensor; electronic charge sensing; floating gate transistor;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2011.2149514
  • Filename
    5762313