• DocumentCode
    1508519
  • Title

    Space-time segmentation using level set active contours applied to myocardial gated SPECT

  • Author

    Debreuve, Éric ; Barlaud, Michel ; Aubert, Gilles ; Laurette, Ivan ; Darcourt, Jacques

  • Author_Institution
    Lab. I3S, Nice Univ., Sophia Antipolis, France
  • Volume
    20
  • Issue
    7
  • fYear
    2001
  • fDate
    7/1/2001 12:00:00 AM
  • Firstpage
    643
  • Lastpage
    659
  • Abstract
    This paper presents a new variational method for the segmentation of a moving object against a still background, over a sequence of [two-dimensional or three-dimensional (3-D)] image frames. The method is illustrated in application to myocardial gated single photon emission computed tomography (SPECT) data, and incorporates a level set framework to handle topological changes while providing closed boundaries. The key innovation is the introduction of a geometrical constraint into the derivation of the Euler-Lagrange equations, such that the segmentation of each individual frame can be interpreted as a closed boundary of an object (an isolevel of a set of hyper-surfaces) while integrating information over the entire sequence. This results in the definition of an evolution velocity normal to the object boundary. Applying this method to 3-D myocardial gated SPECT sequences, the left ventricle endocardial and epicardial limits can be computed in each frame. This space-time segmentation method was tested on simulated and clinical 3-D myocardial gated SPECT sequences and the corresponding ejection fractions were computed.
  • Keywords
    cardiology; image segmentation; medical image processing; muscle; single photon emission computed tomography; 3-D myocardial gated SPECT sequences; Euler-Lagrange equations; ejection fractions; epicardial limits; evolution velocity; geometrical constraint; information integration; isolevel; level set active contours; medical diagnostic imaging; myocardial gated SPECT; nuclear medicine; space-time segmentation; topological changes handling; Active contours; Computational modeling; Equations; Image segmentation; Level set; Monitoring; Myocardium; Single photon emission computed tomography; Technological innovation; Testing; Algorithms; Gated Blood-Pool Imaging; Heart; Humans; Image Processing, Computer-Assisted; Imaging, Three-Dimensional; Mathematics; Movement; Myocardium; Phantoms, Imaging; Stroke Volume; Tomography, Emission-Computed, Single-Photon;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.932748
  • Filename
    932748