Abstract :
A nonlinear finite element model was developed to investigate the manner of the load transfer between the above-knee residual limb and its prosthetic socket. The model was two-dimensional (2-D) with consideration of nonlinear boundary conditions and large deformation. Interface elements were used to simulate the friction/slip conditions between skin and the socket. Different distal-end conditions, including air cushion distal-end loading, were simulated to explore their influences on the load transfer
Keywords :
artificial limbs; biomechanics; finite element analysis; friction; skin; above-knee residual limb; air cushion distal-end loading; distal-end boundary conditions; friction/slip conditions; interface elements; interface friction; large deformation; load transfer; nonlinear boundary conditions; nonlinear finite element model; prosthetic socket; skin; two-dimensional model; Biological tissues; Boundary conditions; Deformable models; Finite element methods; Friction; Knee; Prosthetics; Residual stresses; Skin; Sockets;
fLanguage :
English
Journal_Title :
Rehabilitation Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
1063-6528
Type :
jour
DOI :
10.1109/86.547935
Filename :
547935
Link To Document :
بازگشت