• DocumentCode
    1509409
  • Title

    Schwarz-Christoffel analysis of cable conduits with noncontacting cover

  • Author

    van Deursen, A.P.J.

  • Author_Institution
    Dept. of Electr. Eng., Eindhoven Univ. of Technol.
  • Volume
    37
  • Issue
    13
  • fYear
    2001
  • fDate
    6/21/2001 12:00:00 AM
  • Firstpage
    816
  • Lastpage
    817
  • Abstract
    Metallic trays and conduits protect bundles of cables in electrotechnical installations by diversion of interference currents. The relevant parameter is the conduit transfer impedance Zi. Conformal transformations yield the inductive part M of Zi for conduits with noncontacting covers. Analytical approximations for M agree well with measurements
  • Keywords
    cable sheathing; electric conduits; interference suppression; Schwarz-Christoffel analysis; cable conduits; conduit transfer impedance; conformal transformations; electrotechnical installations; interference current diversion; noncontacting cover;