DocumentCode :
1510054
Title :
Detection of air in helium filled thermal conduction modules
Author :
O´Hanlon, John F.
Author_Institution :
IBM Thomas J. Watson Res. Center, Yorktown Heights, NY, USA
Volume :
14
Issue :
1
fYear :
1991
fDate :
3/1/1991 12:00:00 AM
Firstpage :
211
Lastpage :
213
Abstract :
Two thermal conductance techniques for detecting air contamination in a helium-filled thermal conduction module (TCM) used to package silicon chips are described. A silicon majority carrier thermistor was used to detect as little as 15% air contamination in a container filled with helium. The technique directly measured the internal cooling ability of the package. Both a static test and a transient test were developed. The transient test is shown to be independent of the thermistor packaging. The technique did not require any modification to a TCM. Most importantly, the technique directly measured the cooling ability of the fill gas. The measurement could be performed simply and routinely after assembly, or on return from the field
Keywords :
cooling; helium; modules; packaging; production testing; thermal resistance measurement; He filled thermal conduction modules; Si chips packaging; Si majority carrier thermistor; TCM; air contamination detection; internal cooling ability; routine test method; static test; transient test; Containers; Contamination; Cooling; Helium; Packaging; Pollution measurement; Silicon; Testing; Thermal conductivity; Thermistors;
fLanguage :
English
Journal_Title :
Components, Hybrids, and Manufacturing Technology, IEEE Transactions on
Publisher :
ieee
ISSN :
0148-6411
Type :
jour
DOI :
10.1109/33.76534
Filename :
76534
Link To Document :
بازگشت