• DocumentCode
    1512203
  • Title

    Arbitrary placement array coil system

  • Author

    Molyneaux, David A. ; Qureshi, A. Haq

  • Author_Institution
    NMR Technol. Center, Picker Int., Cleveland, OH, USA
  • Volume
    33
  • Issue
    5
  • fYear
    1997
  • fDate
    9/1/1997 12:00:00 AM
  • Firstpage
    4104
  • Lastpage
    4106
  • Abstract
    A multiple RF coil system was developed for use in an arbitrary polarized NMR imaging system to maximize signal to noise ratio over a given field of view. Conceptual coil conductor patterns were formulated, a theoretical analysis of magnetic field patterns was performed, and mutual inductance between coils was calculated and minimized. A prototype based on the theoretical work was constructed. Test results with the prototype were acquired to verify the theoretical work performed
  • Keywords
    NMR imaging; arrays; coils; NMR imaging; arbitrary placement array; magnetic field; multiple RF coil system; mutual inductance; signal to noise ratio; Coils; Conductors; Magnetic analysis; Magnetic resonance imaging; Pattern analysis; Performance analysis; Polarization; Prototypes; Radio frequency; Signal to noise ratio;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.619677
  • Filename
    619677