Multiplexed Eighty Channel PMT List-Mode Data Acquisition System for 27–511 keV Gamma Ray Imaging
Author :
Tapias, G. ; Villena, J.L. ; Kreuger, R. ; Lage, E. ; Beekman, F.J.
Author_Institution :
Sect. of Radiat. Detection & Med. Imaging, Delft Univ. of Technol., Delft, Netherlands
Volume :
59
Issue :
3
fYear :
2012
fDate :
6/1/2012 12:00:00 AM
Firstpage :
545
Lastpage :
551
Abstract :
We have developed an 80-channel readout system for gamma cameras which acquires PMT signals and stores them in list-mode format on a computer. The system combines low noise and a large signal range to handle PMT signals from a wide range of SPECT and PET tracers simultaneously (27 to 511 keV). All channels of the read-out system have a gated integrator to determine the charge per event. Each 16 channels are multiplexed to a 12-bit 40 MS/s pipelined ADCs. Using multiplexing only 5 ADCs are needed which share a commercial USB 2.0 interface board to send the event data to the computer. The signal input range is up to 120 pC with a noise level of 57 fC. The integral non-linearity is better than 1% for all channels, while the channel response has a gain non-uniformity less than 2.4% for the different channels. The crosstalk between channels is better than 64 dB. The dead time is 2.5 μs, including a 760 ns integration period. The system can handle a sustained event rate of 155 kcps on the USB 2.0 bus. Connected to a clinical gamma camera we show that the isotopes 125I (27-35 keV), 99mTc (140.5 keV) and 22Na (511 keV) can all be imaged without electronic adjustments thus enabling, for instance, simultaneous pinhole PET/SPECT. With this PMT list-mode acquisition system, advanced offline event positioning and energy estimation with e.g. maximum likelihood methods are enabled.
Keywords :
analogue-digital conversion; data acquisition; gamma-ray detection; integrating circuits; nuclear electronics; photomultipliers; positron emission tomography; radioactive tracers; readout electronics; single photon emission computed tomography; 125I isotope; 22Na isotope; 99mTc isotope; ADC; PET simultaneous pinhole; PET tracers; PMT list-mode acquisition system; PMT signals; SPECT simultaneous pinhole; SPECT tracers; USB 2.0 interface board; advanced offline event positioning; channel crosstalk; channel response; clinical gamma camera; data acquisition system; dead time; electron volt energy 27 keV to 511 keV; electronic adjustments; energy estimation; gain nonuniformity; gamma cameras; gamma ray imaging; gated integrator; integral nonlinearity; integration period; list-mode format; maximum likelihood methods; multiplexed eighty channel PMT list-mode; noise level; readout system; signal input range; sustained event rate; time 2.5 mus; time 760 ns; Cameras; Data acquisition; Field programmable gate arrays; Logic gates; Multiplexing; Registers; Universal Serial Bus; Data acquisition system (DAQ); gated integrator; list-mode; small animal SPECT;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2012.2193596
Filename :
6197249
Link To Document :
بازگشت