DocumentCode
1513496
Title
44-MW four-pole motor selected for compressor drive
Author
Grieve, Derek ; Buss, E. William ; Emery, Richard ; Wright, Kevin D.
Author_Institution
ALSTOM Electr. Machines Ltd., Rugby, UK
Volume
35
Issue
3
fYear
1999
Firstpage
675
Lastpage
681
Abstract
This paper details the considerations that went into the design, procurement and installation of the main air compressor electrical package for the world´s largest single-train air separation facility. It further details the method of starting and factors that make a 44 MW (59,000 hp) four-pole motor a feasible proposition
Keywords
compressors; design engineering; installation; motor drives; 44 MW; 59000 hp; air compressor drive; applications; design; four-pole motor; installation; procurement; single-train air separation facility; starting; Chemical industry; Costs; Fuels; Heating; Maintenance; Packaging; Petroleum; Procurement; Substations; Synchronous motors;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.767021
Filename
767021