DocumentCode
1513669
Title
Eigendecomposition-Based Clutter Filtering Technique for Optical Microangiography
Author
Yousefi, S. ; Zhongwei Zhi ; Wang, R.K.
Author_Institution
Dept. of Electr. Eng., Univ. of Washington, Seattle, WA, USA
Volume
58
Issue
8
fYear
2011
Firstpage
2316
Lastpage
2323
Abstract
In this paper, we propose eigendecposition (ED)-based clutter filtering technique for 3-D optical imaging of blood flow. Due to its best mean-square approximation of the clutter, eigenregression filters can theoretically provide maximum clutter suppression. Compared to the existing clutter rejection techniques in the literature used for optical imaging of blood flow, ED-based clutter filtering is less sensitive to tissue motion and can efficiently suppress the clutter while preserving the flow information. Therefore, it creates images with better contrast in the presence of bulk motion. The performance of the proposed ED-based technique is compared with that of phase-compensation method and static high-pass filtering. The quantitative and qualitative performances are compared with each other in phantom studies and in vivo imaging, respectively. Also, 3-D image of microvascular structures in mouse ear is presented, where the clutter has been suppressed with ED-based technique. This technique can be used in applications, where involuntary movements due to cardiac and respiratory cycles are inevitable (such as retinal imaging).
Keywords
biomedical optical imaging; eigenvalues and eigenfunctions; filtering theory; haemodynamics; medical image processing; phantoms; 3D optical imaging; blood flow; cardiac cycle; clutter rejection techniques; eigendecomposition-based clutter filtering; mean-square approximation; microvascular structure; mouse ear; optical microangiography; phase-compensation method; respiratory cycle; static high-pass filtering; tissue motion; Adaptive filters; Blood flow; Clutter; Doppler effect; Optical filters; Optical imaging; Clutter rejection; eigenregression filters; filters; frequency-domain optical coherence tomography (FDOCT); optical microangiography (OMAG); Algorithms; Animals; Blood Flow Velocity; Ear; Image Enhancement; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Mice; Reproducibility of Results; Rheology; Sensitivity and Specificity;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2011.2152839
Filename
5765664
Link To Document