• DocumentCode
    1513738
  • Title

    Impact of Saturation, Current Command Selection, and Leakage Flux on the Performance of Sensorless-Controlled Three-Pole Active Magnetic Bearings

  • Author

    García, Pablo ; Guerrero, Juan M. ; Mahmoud, Islam El-Sayed ; Briz, Fernando ; Reigosa, David Díaz

  • Author_Institution
    Dept. of Electr., Univ. of Oviedo, Gijon, Spain
  • Volume
    47
  • Issue
    4
  • fYear
    2011
  • Firstpage
    1732
  • Lastpage
    1740
  • Abstract
    This paper analyzes two types of effects caused by the fundamental current in saliency-tracking-based techniques for sensorless control of three-pole active magnetic bearings, i.e., saturation and insufficient spectral separation of the fundamental current command during transients. Injection of a high-frequency signal superimposed to the fundamental excitation providing active control allows the measurement of changes in the air gap, from which an estimation of the rotor position can be obtained. Interference of the fundamental current, which is needed to operate the magnetic bearing, with the high-frequency current can occur through two mechanisms: 1) saturation; and 2) high-frequency harmonics caused by fast transients of the fundamental current. Both phenomena can interfere with the sensorless control resulting in a decrease in its performance. The effects caused by the fundamental current on the negative-sequence high-frequency current, used as a position estimation signal, are studied, and a decoupling mechanism is proposed. An analysis of high-frequency leakage flux is presented. and a simple analytical model is developed for describing the aforementioned phenomena. Finite-element analysis of the magnetic bearing under fundamental excitation, as well as experimental verification, is used to validate the analytical findings.
  • Keywords
    finite element analysis; machine bearings; magnetic bearings; rotors; sensorless machine control; current command selection; finite element analysis; fundamental excitation; high-frequency current; high-frequency harmonics; leakage flux; position estimation signal; rotor position; saliency tracking; sensorless control; spectral separation; three-pole active magnetic bearings; Coils; Current measurement; Force; Frequency measurement; Inductance; Magnetic levitation; Rotors; Active magnetic bearings; kinetic energy storage; saliency tracking; sensorless control;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2011.2153814
  • Filename
    5765675