• DocumentCode
    1513969
  • Title

    Development of a PET-Transrectal Ultrasound Prostate Imaging System

  • Author

    Huber, Jennifer S. ; Peng, Qiyu ; Moses, William W. ; Reutter, Bryan W. ; Pouliot, Jean ; Hsu, I. Chow

  • Author_Institution
    Lawrence Berkeley Nat. Lab., Berkeley, CA, USA
  • Volume
    58
  • Issue
    3
  • fYear
    2011
  • fDate
    6/1/2011 12:00:00 AM
  • Firstpage
    674
  • Lastpage
    681
  • Abstract
    Multimodality imaging has an increasing role in the management of a large number of diseases, particularly if both functional and structural information are acquired and accurately registered. Transrectal ultrasound (TRUS) imaging is currently an integral part of prostate cancer diagnosis and treatment procedures, providing high-resolution anatomical detail of the prostate region. Positron Emission Tomography (PET) imaging with 11C-choline is a sensitive functional imaging technique that can identify biochemical states associated with prostate cancer. We believe that merging these prostate imaging technologies will help identify the location and aggressiveness of prostate cancer. We envision using dual PET-TRUS prostate imaging to guide biopsy, guide treatment procedures, and detect local recurrence earlier than is currently possible. Hence, we have developed a dual PET-TRUS prostate imaging system and protocol designed to allow accurate 3-D image registration. We have evaluated this PET-TRUS system by performing dual PET-TRUS imaging of custom phantoms. We describe here our dual-modality imaging system, custom phantoms and phantom study results. We also discuss our investigation of the PET-TRUS registration accuracy. We measure an average PET-TRUS registration error for our phantom studies of 2.1 ±1.7 mm in the x direction, 1.9 ±1.6 mm in the y direction, and 0.6 ±0.2 mm in the z direction. This registration accuracy is sufficient for some clinical applications such as biopsy guidance and early detection of recurrence.
  • Keywords
    biological organs; biomedical ultrasonics; cancer; image registration; medical image processing; phantoms; positron emission tomography; 11C-choline PET imaging; 3D image registration; PET-TRUS prostate imaging system; PET-TRUS registration accuracy; biochemical states; biopsy guidance; dual PET-TRUS prostate imaging; functional information; high resolution anatomical data; local cancer recurrence detection; multimodality imaging; phantoms; positron emission tomography; prostate cancer; structural information; transrectal ultrasound imaging; treatment guidance; Electron tubes; Imaging phantoms; Phantoms; Positron emission tomography; Probes; Ultrasonic imaging; Cancer; image registration; positron emission tomography; ultrasound;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2011.2136387
  • Filename
    5765715