Title :
Analysis of effects of three-phase voltage unbalance on induction motors with emphasis on the angle of the complex voltage unbalance factor
Author_Institution :
Dept. of Electr. Eng., Nat. Yun-Lin Univ. of Sci. & Technol., Yun-Lin, Taiwan
fDate :
9/1/2001 12:00:00 AM
Abstract :
Analysis of the steady-state performance of an induction motor connected to unbalanced three-phase voltages is presented. The index of voltage unbalance used in this paper is the complex voltage unbalance factor (CVUF) that consists of the magnitude and the angle. In addition to formulation and discussion of the motor operating characteristics under voltage unbalance, special emphasis is placed on the effect of the angle of the CVUF on the motor. It is found that the angle of the CVUF is also an important factor that merits particular attention in analyzing voltage unbalance issues
Keywords :
harmonic distortion; induction motors; load (electric); machine theory; power supply quality; power system harmonics; complex voltage unbalance factor angle; induction motors; motor operating characteristics; steady-state performance; three-phase voltage unbalance effects; IEC; Induction motors; Performance analysis; Power quality; Power supplies; Power system analysis computing; Protection; Steady-state; Traction motors; Voltage;
Journal_Title :
Energy Conversion, IEEE Transactions on