• DocumentCode
    1516647
  • Title

    Verification of ISFET response time for millisecond range ion stimulus using electronic technique

  • Author

    Thanapitak, Surachoke ; Pookaiyaudom, P. ; Seelanan, P. ; Lidgey, F.J. ; Hayatleh, K. ; Toumazou, Christofer

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Imperial Coll. London, London, UK
  • Volume
    47
  • Issue
    10
  • fYear
    2011
  • Firstpage
    586
  • Lastpage
    588
  • Abstract
    The ion sensitive field effect transistor (ISFET) is a popular sensor in biomedical electronics and has been used to date mainly for relatively low speed applications, such as measurement of pH of common biomedical fluids. However, there is a growing interest in sensing rapidly changing ion activity for applications including chemical synapse and rapid DNA sequencing. In this reported work, it is demonstrated that the response time of the ISFET is sufficient for these applications. The results obtained are used to determine the factors that affect high speed chemical sensing with the ISFET.
  • Keywords
    biomedical electronics; chemical sensors; ion sensitive field effect transistors; ISFET response time; biomedical electronics; common biomedical fluids; electronic technique; high speed chemical sensing; ion sensitive field effect transistor; millisecond range ion stimulus;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el.2011.0608
  • Filename
    5767235