Title :
Improving the Gait Performance of Nonfluid-Based Swing-Phase Control Mechanisms in Transfemoral Prostheses
Author :
Furse, A. ; Cleghorn, W. ; Andrysek, J.
Author_Institution :
Inst. of Biomater. & Biomed. Eng., Univ. of Toronto, Toronto, ON, Canada
Abstract :
A prosthetic swing-phase control mechanism simulates the action of leg musculature, aiding gait function by controlling the duration of swing, extent of heel rise, and by allowing the shank to smoothly decelerate into full knee extension without excessive impact. Nonfluid-based (NBF) mechanisms have the potential to provide a durable and affordable solution as required in many parts of the world, but the design variables that lead to improved performance of NBF swing-phase control technologies are not well established. Seven transfemoral amputees were fitted with a prosthetic knee joint and different NBF swing-phase setups were systematically assessed. Clinical testing included walk tests utilizing a potentiometer (to measure knee flexion angles) and accelerometer (to measure terminal impact decelerations) mounted on the prosthetic limb. As hypothesized, the friction and spring systems improved gait function. This includes an increased walking speed that closely matched high-end hydraulic prosthetic knee joints, decreased and more normal maximum prosthetic knee flexion, decreased flexion duration, and lower terminal impact. Further improvements were obtained using a dual-spring system, two springs in series, over the more conventional single spring system. NBF swing-phase control mechanisms are simple and significantly improve the performance of prostheses. Their application is ideal where size, weight, and cost may be constrained.
Keywords :
acceleration measurement; accelerometers; angular measurement; artificial limbs; biomechanics; biomedical measurement; handicapped aids; medical control systems; motion control; potentiometers; springs (mechanical); accelerometer; flexion duration; friction-spring system; full knee extension; gait function aid; gait function improvement; gait performance; heel rise extent control; knee flexion angle measurement; leg musculature action simulation; nonfluid based mechanisms; nonfluid based swing phase control mechanisms; potentiometer; prosthetic knee flexion; prosthetic knee joint; prosthetic limb; prosthetic swing phase control mechanism; smooth shank deceleration; swing duration control; terminal impact deceleration measurement; transfemoral amputees; transfemoral prostheses; walk tests; walking speed; Feedback amplifier; Friction; Knee; Legged locomotion; Prosthetics; Springs; Testing; Above knee; amputation; amputee; control; gait; knee joint; prostheses; prosthetic; swing; swing-phase control; transfemoral; Amputation Stumps; Amputees; Artificial Limbs; Equipment Failure Analysis; Feedback; Gait; Gait Disorders, Neurologic; Humans; Leg; Prosthesis Design; Rheology; Treatment Outcome;
Journal_Title :
Biomedical Engineering, IEEE Transactions on
DOI :
10.1109/TBME.2011.2155059