• DocumentCode
    1517628
  • Title

    The PANDA Electromagnetic Calorimeter—A High-Resolution Detector Based on PWO-II

  • Author

    Novotny, R.W. ; Bremer, D. ; Dormenev, V. ; Döring, W. ; Eissner, T. ; Korzhik, M. ; Kuske, T. ; Missevitch, O. ; Moritz, M.

  • Author_Institution
    2nd Phys. Inst., Univ. Giessen, Giessen, Germany
  • Volume
    57
  • Issue
    3
  • fYear
    2010
  • fDate
    6/1/2010 12:00:00 AM
  • Firstpage
    1441
  • Lastpage
    1446
  • Abstract
    The electromagnetic calorimeter of the PANDA detector at the future Facility for Antiproton and Ion Research is one of the central components to measure high-energy photons over a wide dynamic range down to a few tens of mega–electron volts. The calorimeter comprises almost 16 000 PWO-II crystals of 200 mm length with high quality standards in optical performance, light output, and radiation hardness. The running mass production has passed more than 7000 crystals. The observation of stimulated recovery even of cooled crystals by illumination with external light sources integrated into the detector modules has opened up a new design concept for PANDA and future calorimeters.
  • Keywords
    Detectors; Dynamic range; Electromagnetic compatibility; Electromagnetic measurements; Forward contracts; Photonic crystals; Physics; Shape measurement; Spectroscopy; Temperature measurement; Calorimetry; lead tungstate; radiation damage; radiation detectors; scintillator;