• DocumentCode
    1518059
  • Title

    ASIC for High Rate 3D Position Sensitive Detectors

  • Author

    Vernon, Emerson ; Ackley, Kim ; De Geronimo, Gianluigi ; Fried, Jack ; He, Zhong ; Herman, Cedric ; Zhang, Feng

  • Author_Institution
    Instrum. Div., Brookhaven Nat. Lab., Upton, NY, USA
  • Volume
    57
  • Issue
    3
  • fYear
    2010
  • fDate
    6/1/2010 12:00:00 AM
  • Firstpage
    1536
  • Lastpage
    1542
  • Abstract
    We report on the development of an application specific integrated circuit (ASIC) for 3D position sensitive detectors (3D PSD). The ASIC is designed to operate with pixelated wide bandgap sensors like Cadmium-Zinc-Telluride (CZT), Mercuric Iodide (Hgl2) and Thallium Bromide (TIBr). It measures the amplitudes and timings associated with an ionizing event on 128 anodes, the anode grid, and the cathode. Each channel provides low-noise charge amplification, high-order shaping with peaking time adjustable from 250 ns to 12 μs, gain adjustable to 20 mV/fC or 120 mV/fC (for a dynamic range of 3.2 MeV and 530 keV in CZT), amplitude discrimination with 5-bit trimming, and positive and negative peak and timing detections. The readout can be full or sparse, based on a flag and single- or multi-cycle token passing. All channels, triggered channels only, or triggered with neighbors can be read out thus increasing the rate capability of the system to more than 10 kcps. The ASIC dissipates 330 mW which corresponds to about 2.5 mW per channel.
  • Keywords
    application specific integrated circuits; nuclear electronics; position sensitive particle detectors; readout electronics; semiconductor counters; 3D position sensitive detector; ASIC; application specific integrated circuit; cadmium-zinc-telluride; high-order shaping; low-noise charge amplification; mercuric iodide; multicycle token; pixelated wide bandgap sensors; single-cycle token; thallium bromide; triggered channels; Application specific integrated circuits; Gamma ray detection; Gamma ray detectors; Helium; Photonic band gap; Position sensitive particle detectors; Temperature sensors; Timing; X-ray detection; X-ray detectors; 3D; Thallium Bromide (TlBr); application specific integrated circuit (ASIC); cadmium-zinc-telluride (CZT); charge collection; gamma-ray camera; mercuric iodide (HgI$_{2}$ ); solid state detectors; timing; x-ray spectroscopy;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2010.2047026
  • Filename
    5485173