• DocumentCode
    15184
  • Title

    Fluid Embeddable Coupled Coil Sensor for Wireless pH Monitoring in a Bioreactor

  • Author

    Bhadra, S. ; Blunt, Warren ; Dynowski, Chris ; McDonald, M. ; Thomson, David J. ; Freund, Michael S. ; Cicek, Nihan ; Bridges, Greg E.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Manitoba, Winnipeg, MB, Canada
  • Volume
    63
  • Issue
    5
  • fYear
    2014
  • fDate
    May-14
  • Firstpage
    1337
  • Lastpage
    1346
  • Abstract
    A passive embeddable coupled coil sensor for remote bioprocess pH monitoring is described. The sensor is sterilizable, able to operate in a fluid medium, and small enough to fit inside a small bioreactor or test tube. It consists of a planar spiral inductor connected parallel to a varactor forming an LC resonant circuit. A pH combination electrode made of an iridium/iridium oxide sensing electrode and a silver/silver chloride reference electrode is connected parallel to the varactor. A potential difference change across the electrodes due to pH variation of the medium changes the voltage-dependent capacitance and shifts the resonant frequency of the sensor. An interrogator coil is inductively coupled to the sensor coil and remotely tracks the resonant frequency of the sensor. For in-fluid monitoring, the sensor is encapsulated in a manner that reduces the influence of the permittivity and conductivity of the medium. The sensor, calibrated over 2-12 pH range, exhibits a rapid response with 2.477-MHz/pH sensitivity. The sensor was used for remote pH monitoring of Yarrowia lipolytica and Saccharomyces cerevisiae fermentation in a shake flask over 63 and 25 h, respectively. The experiments demonstrate that the medium pH can be monitored repeatedly with an accuracy of 0.08 pH.
  • Keywords
    LC circuits; bioreactors; chemical sensors; coils; fermentation; pH measurement; varactors; LC resonant circuit; bioreactor; fluid embeddable coupled coil sensor; interrogator coil; iridium-iridium oxide sensing electrode; pH combination electrode; passive embeddable coupled coil sensor; planar spiral inductor; resonant frequency; saccharomyces cerevisiae fermentation; shake flask; silver-silver chloride reference electrode; test tube; varactor; voltage-dependent capacitance; wireless pH monitoring; yarrowia lipolytica; Coils; Electrodes; Impedance; Inductors; Monitoring; Resonant frequency; Sensors; Bioreactor; coupled coil; in-fluid; pH sensor; passive; saccharomyces cerevisiae; wireless; yarrowia lipolytica;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2013.2292279
  • Filename