DocumentCode
1518885
Title
Information-Theoretic Approach for Analyzing Bias and Variance in Lung Nodule Size Estimation With CT: A Phantom Study
Author
Gavrielides, Marios A. ; Zeng, Rongping ; Kinnard, Lisa M. ; Myers, Kyle J. ; Petrick, Nicholas
Author_Institution
Div. of Imaging & Appl. Math. (DIAM), U.S. Food & Drug Adm. (FDA), Silver Spring, MD, USA
Volume
29
Issue
10
fYear
2010
Firstpage
1795
Lastpage
1807
Abstract
This work is a part of our more general effort to probe the interrelated factors impacting the accuracy and precision of lung nodule measurement tasks. For such a task a low-bias size estimator is needed so that the true effect of factors such as acquisition and reconstruction parameters, nodule characteristics and others can be assessed. Towards this goal, we have developed a matched filter based on an adaptive model of the object acquisition and reconstruction process. Our model derives simulated reconstructed data of nodule objects (templates) which are then matched to computed tomography data produced from imaging the actual nodule in a phantom study using corresponding imaging parameters. This approach incorporates the properties of the imaging system and their effect on the discrete 3-D representation of the object of interest. Using a sum of absolute differences cost function, the derived matched filter demonstrated low bias and variance in the volume estimation of spherical synthetic nodules ranging in density from -630 to +100 HU and in size from 5 to 10 mm. This work could potentially lead to better understanding of sources of error in the task of lung nodule size measurements and may lead to new techniques to account for those errors.
Keywords
computerised tomography; diagnostic radiography; image reconstruction; information theory; lung; matched filters; medical image processing; phantoms; CT; computed tomography; information theory; lung nodule size estimation; matched filter; object acquisition; phantom; reconstruction; size 5 mm to 10 mm; spherical synthetic nodules; Analysis of variance; Computed tomography; Cost function; Image reconstruction; Imaging phantoms; Information analysis; Lungs; Matched filters; Probes; Size measurement; Lung nodule; matched filter; phantom study; thoracic computed tomography (CT); volume estimation; Algorithms; Analysis of Variance; Humans; Information Theory; Lung Neoplasms; Radiographic Image Enhancement; Radiographic Image Interpretation, Computer-Assisted; Reproducibility of Results; Sensitivity and Specificity; Solitary Pulmonary Nodule; Tomography, X-Ray Computed;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2010.2052466
Filename
5487376
Link To Document