• DocumentCode
    1519607
  • Title

    A traceable mains-frequency power standard

  • Author

    Corney, Andrew C.

  • Author_Institution
    Meas. Stand. Lab., Ind. Res. Ltd., Lower Hutt, New Zealand
  • Volume
    48
  • Issue
    2
  • fYear
    1999
  • fDate
    4/1/1999 12:00:00 AM
  • Firstpage
    418
  • Lastpage
    421
  • Abstract
    A mains-frequency power standard traceable to voltage and impedance standards has been realized. One-sigma uncertainties are 19 μW/W at unity power factor, and 22 μW/W at zero power factor. A power bridge balanced to 0.2% is augmented by fast Fourier transform (FFT) analysis of samples of the detector voltage, eliminating the influence of harmonics and drift in the test sources
  • Keywords
    bridge circuits; calibration; digital voltmeters; energy measurement; fast Fourier transforms; measurement uncertainty; power measurement; transfer standards; watthour meters; wattmeters; FFT analysis; balanced power bridge; current shunt; digital voltmeter; energy standard; impedance standards; inductive voltage divider; mains-frequency power standard; one-sigma uncertainties; resistive voltage divider; traceable standard; unity power factor; voltage standards; watt-hour meter calibration; wattmeter; zero power factor; Bridge circuits; Detectors; Fast Fourier transforms; Harmonic analysis; Impedance; Power system harmonics; Reactive power; Testing; Uncertainty; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.769615
  • Filename
    769615