• DocumentCode
    1519646
  • Title

    New measurement capabilities of the NRC traveling standard program

  • Author

    Arseneau, Rejean ; Filipski, Piotr ; Zelle, John

  • Author_Institution
    Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
  • Volume
    48
  • Issue
    2
  • fYear
    1999
  • fDate
    4/1/1999 12:00:00 AM
  • Firstpage
    444
  • Lastpage
    446
  • Abstract
    This paper describes the improvements made to the National Research Council of Canada (NRC) Watt-VA Transfer Standard and to the AC source, which are used to support the NRC Traveling Standard Program. With these improvements, NRC clients can now calibrate on-site the voltage, current, active, reactive, and apparent power functions of their standards for rms voltages up to 600 V and rms currents up to 50 A
  • Keywords
    calibration; current comparators; current transformers; electric current measurement; power measurement; transfer standards; voltage measurement; wattmeters; waveform generators; AC source; NRC traveling standard program; Watt-VA transfer standard; active power function; apparent power function; current function; digital waveform generators; improved measurement capabilities; on-site calibration; pulse-frequency comparator; reactive power function; reference meter; step-up current transformer; voltage function; Calibration; Councils; Current measurement; Current transformers; Government; Measurement standards; Potentiometers; Power industry; Voltage; Watthour meters;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.769621
  • Filename
    769621