DocumentCode
1520354
Title
Available insulation systems for PWM inverter-fed motors
Author
Bonnett, Austin H.
Volume
4
Issue
1
fYear
1998
Firstpage
14
Lastpage
26
Abstract
This article focuses specifically on integral horsepower AC induction motors used in the pulp and paper industry. An analysis of the various winding stresses is presented. The different requirements for the two insulation systems are discussed (MG1-Parts 30 and 31 For General Purpose and Definite Purpose Inverter Fed Motors), and test results show the need for higher dielectric insulation when the voltage levels of Part 30 are exceeded. The differences between existing, rebuilt and new motors are also explored. To assist the reader with additional research, an extensive reference section is provided
Keywords
DC-AC power convertors; PWM invertors; induction motors; machine insulation; machine windings; paper industry; standards; PWM inverters; dielectric insulation; insulation systems; integral horsepower induction motors; paper industry; pulp industry; standards; winding stresses; Dielectrics and electrical insulation; Electric breakdown; Induction motors; Insulated gate bipolar transistors; Insulation testing; Pulp and paper industry; Pulse width modulation inverters; Stress; System testing; Variable speed drives;
fLanguage
English
Journal_Title
Industry Applications Magazine, IEEE
Publisher
ieee
ISSN
1077-2618
Type
jour
DOI
10.1109/2943.644882
Filename
644882
Link To Document