• DocumentCode
    1520354
  • Title

    Available insulation systems for PWM inverter-fed motors

  • Author

    Bonnett, Austin H.

  • Volume
    4
  • Issue
    1
  • fYear
    1998
  • Firstpage
    14
  • Lastpage
    26
  • Abstract
    This article focuses specifically on integral horsepower AC induction motors used in the pulp and paper industry. An analysis of the various winding stresses is presented. The different requirements for the two insulation systems are discussed (MG1-Parts 30 and 31 For General Purpose and Definite Purpose Inverter Fed Motors), and test results show the need for higher dielectric insulation when the voltage levels of Part 30 are exceeded. The differences between existing, rebuilt and new motors are also explored. To assist the reader with additional research, an extensive reference section is provided
  • Keywords
    DC-AC power convertors; PWM invertors; induction motors; machine insulation; machine windings; paper industry; standards; PWM inverters; dielectric insulation; insulation systems; integral horsepower induction motors; paper industry; pulp industry; standards; winding stresses; Dielectrics and electrical insulation; Electric breakdown; Induction motors; Insulated gate bipolar transistors; Insulation testing; Pulp and paper industry; Pulse width modulation inverters; Stress; System testing; Variable speed drives;
  • fLanguage
    English
  • Journal_Title
    Industry Applications Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    1077-2618
  • Type

    jour

  • DOI
    10.1109/2943.644882
  • Filename
    644882