    Reduction of Interference Between pH and Optical Output Signals in a Multimodal Bio-Image Sensor

  • Author

    Nakazawa, Hirokazu ; Ishida, Makoto ; Sawada, Kazuaki

  • Author_Institution
    Integrated Circuit & Sensor Syst. Group, Toyohashi Univ. of Technol., Toyohashi, Japan
  • Volume
    11
  • Issue
    11
  • fYear
    2011
  • Firstpage
    2718
  • Lastpage
    2722
  • Abstract
    A low-interference multimodal sensor for pH and optical imaging has been developed. The interference signal that occurs between pH and the optical outputs is found to be caused by photogenerated electrons during pH sensing. This interference could be suppressed by adding another charge-accumulation region to a conventional multimodal sensor structure in order to measure only photogenerated electrons. Conventional pH sensing devices combine accumulation regions for photo generated electrons, thereby discriminating between pH and optical signals.
  • Keywords
    biosensors; chemical sensors; image sensors; interference (signal); pH measurement; interference reduction; multimodal bioimage sensor; optical output signals; pH sensing; photogenerated electrons; Electric potential; Image sensors; Interference; Optical buffering; Optical imaging; Optical sensors; CMOS integrated circuits; Charge transfer image sensors; visual system;