• DocumentCode
    1522554
  • Title

    Quantification of injury-related EEG signal changes using distance measures

  • Author

    Kong, Xuan ; Brambrink, Ansgar ; Hanley, Daniel F. ; Thakor, Nitish V.

  • Author_Institution
    Dept. of Electr. Eng., Northern Illinois Univ., DeKalb, IL, USA
  • Volume
    46
  • Issue
    7
  • fYear
    1999
  • fDate
    7/1/1999 12:00:00 AM
  • Firstpage
    899
  • Lastpage
    901
  • Abstract
    Novel indicators based on distance measures are developed and compared to quantify changes in electroencephalogram signal resulting from hypoxic-asphyxic injury. An injury index is derived based on the measures. The Itakura distance-based index is found to have the highest correlation with the long-term outcome as measured by the neurological deficit scores.
  • Keywords
    electroencephalography; medical signal processing; EEG analysis; Itakura distance-based index; distance measures; electrodiagnostics; hypoxic-asphyxic injury; injury-related EEG signal changes quantification; long-term outcome; neurological deficit scores; piglets; Animals; Asphyxia; Blood; Brain injuries; Brain modeling; Electroencephalography; Low pass filters; Monitoring; Power system modeling; Real time systems; Animals; Electroencephalography; Ischemic Attack, Transient; Linear Models; Models, Neurological; Monitoring, Physiologic; Signal Processing, Computer-Assisted; Swine;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.771208
  • Filename
    771208