DocumentCode
1524339
Title
Intermittency phenomena in electrical connectors
Author
Maul, Christian ; McBride, John W. ; Swingler, Jonathan
Author_Institution
Sch. of Eng. Sci., Southampton Univ., UK
Volume
24
Issue
3
fYear
2001
fDate
9/1/2001 12:00:00 AM
Firstpage
370
Lastpage
377
Abstract
Fretting is known to be a major cause of contact deterioration and failure, particularly in tin-plated contacts. During fretting the contact resistance generally increases slowly with time. Superimposed on this slow increase in contact resistance are rapid changes in contact resistance within fractions of a second, called intermittences or short duration discontinuities. Although intermittences have been reported by several authors, they are frequently overlooked in traditional fretting experiments and not much is known about their origin. The present study aims at filling this gap. A test apparatus has been built to measure the contact voltage-drop profile during an intermittence and fretting experiments on tin-plated copper contacts have been carried out. The results lead to a set of requirements for a model to explain intermittency phenomena
Keywords
contact resistance; corrosion; electric connectors; failure analysis; wear; contact deterioration; contact failure; contact resistance; contact voltage-drop profile; electrical connectors; fretting; intermittency phenomena; short duration discontinuities; Circuits; Connectors; Contact resistance; Copper; Electrical resistance measurement; Steady-state; Testing; Thermal stresses; Tin; Voltage;
fLanguage
English
Journal_Title
Components and Packaging Technologies, IEEE Transactions on
Publisher
ieee
ISSN
1521-3331
Type
jour
DOI
10.1109/6144.946482