Abstract :
Hermetically-sealed flexible food packages require very effective seal integrity testing to extend the shelf stability of thermally processed food. The initial goal of this study was to estimate the detection limits of laboratory-generated channels which simulate defects in food packages using pulse-echo ultrasonic imaging techniques. Packages with well characterized (via transmission optical microscopy) laboratory-generated channels that simulate defects with diameters between 9 and 325 /spl mu/m in the seal plane traversing the major axis of the heat seal were generated in heat-sealed microwavable retort-pouch plastic film (trilaminate). Pulse-echo techniques in the 13-17 MHz center frequency range were investigated. The samples were examined with a conventional B-mode imaging technique, which was found to be inadequate for subwavelength imaging of the types of typical channel defects found in shelf-stable food packages. Based on conventional B-mode image features, a new goal of this study was established to develop and evaluate an imaging technique which would exhibit subwavelength imaging capabilities. The new imaging technique called backscattered amplitude integral (BAI) is introduced here. It was observed that BAI-mode imaging has the ability for subwavelength detection of channel defects, e.g., detection of a 10-/spl mu/m diameter channel defect at a center frequency of 13.1 MHz (/spl lambda/=182 /spl mu/m).
Keywords :
backscatter; food processing industry; laminates; packaging; seals (stoppers); ultrasonic imaging; ultrasonic materials testing; 13 to 17 MHz; 9 to 325 micron; B-mode imaging; BAI-mode imaging; backscattered amplitude integral; channel defect detection; food package; hermetic heat seal; integrated backscatter ultrasound imaging; integrity testing; microwavable retort-pouch plastic film; pulse-echo ultrasonic imaging; shelf stability; subwavelength imaging; thermal processing; trilaminate; Frequency; Laboratories; Optical imaging; Optical microscopy; Optical pulses; Packaging; Seals; Testing; Thermal stability; Ultrasonic imaging;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/58.646905
Filename :
646905
Link To Document :
بازگشت