• DocumentCode
    1526643
  • Title

    Hot-wire anemometer with temperature compensation using only one sensor

  • Author

    Ferreira, Rômulo Pires Coelho ; Freire, Raimundo Carlos Silvéiro ; Deep, Gurdip Singh ; de Rocha Neto, J.S. ; Oliveira, Amauri

  • Author_Institution
    UFPB, Brazil
  • Volume
    50
  • Issue
    4
  • fYear
    2001
  • fDate
    8/1/2001 12:00:00 AM
  • Firstpage
    954
  • Lastpage
    958
  • Abstract
    In conventional constant temperature hot-wire anemometers, the compensation for the fluid temperature is done by using two sensors. In this paper, the analysis of an anemometer circuit using only one sensor, operating alternately at two different temperatures is presented. The effect of the amplifier input offset voltage is taken into account, and its influence on the measurement of fluid velocity is quantified. Preliminary experimental results are also presented
  • Keywords
    anemometers; compensation; electric sensing devices; equivalent circuits; flow measurement; thermoelectric devices; amplifier input offset voltage; electrical equivalence; fluid temperature; hot-wire anemometer; measurement of fluid velocity; operational amplifier; temperature compensation; thermoresistive sensor; Circuits; Fluid flow measurement; Resistance heating; Temperature dependence; Temperature sensors; Thermal sensors; Thermoresistivity; Velocity measurement; Voltage; Wire;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.948306
  • Filename
    948306