• DocumentCode
    1528761
  • Title

    Load response of terminated transmission lines exposed to external electromagnetic fields

  • Author

    Papakanellos, P.J. ; Veropoulos, G.P.

  • Volume
    4
  • Issue
    7
  • fYear
    2010
  • fDate
    7/1/2010 12:00:00 AM
  • Firstpage
    917
  • Lastpage
    922
  • Abstract
    Plane-wave excitation fields are by far the most commonly used in field-to-wire coupling computations. Nevertheless, such excitations are not always adequate for the immunity assessment of wire-type structures operating in the contemporary man-made environment. To reinforce this conjecture, this study examines two-wire transmission lines excited by common non-uniform fields. Numerical results for the induced load voltages show notable deviations from those obtained under the assumption of plane-wave incidence.
  • Keywords
    electromagnetic fields; transmission lines; external electromagnetic fields; field-to-wire coupling computations; immunity assessment; load response; plane-wave excitation fields; plane-wave incidence; terminated transmission lines; two-wire transmission lines; wire-type structures;
  • fLanguage
    English
  • Journal_Title
    Microwaves, Antennas & Propagation, IET
  • Publisher
    iet
  • ISSN
    1751-8725
  • Type

    jour

  • DOI
    10.1049/iet-map.2009.0141