• DocumentCode
    152976
  • Title

    High power oscillation experiment of a prototype gyrotron for 300 GHz band collective Thomson scattering diagnostics in LHD

  • Author

    Saito, Takashi ; Yamaguchi, Yoshio ; Tatematsu, Y. ; Kasa, Jun ; Kotera, Masaki ; Ikeuchi, Shinji ; Idehara, T. ; Kubo, Satoshi ; Shimozuma, Takashi ; Tanaka, Kiyoshi ; Nishiura, Masaki

  • Author_Institution
    Res. Center for Dev. of Far-Infrared Region, Univ. of Fukui, Fukui, Japan
  • fYear
    2014
  • fDate
    14-19 Sept. 2014
  • Firstpage
    1
  • Lastpage
    2
  • Abstract
    A high power 300 GHz band pulse gyrotron has been developed for use in the collective Thomson scattering (CTS) diagnostics in Large Helical Device. The design concept for stable and single mode oscillation was experimentally verified with a prototype tube of 295 GHz at the fundamental harmonic. A highest power approaching 250 kW was realized. Based on the results of the prototype tube, design of the next tube is under way for practical use in the CTS experiments.
  • Keywords
    gyrotrons; harmonic oscillators; helical waveguides; LHD; collective Thomson scattering diagnostics; frequency 295 GHz; frequency 300 GHz; high power oscillation experiment; large helical device; prototype gyrotron; single mode oscillation; Cavity resonators; Electron tubes; Gyrotrons; Harmonic analysis; Oscillators; Prototypes; Scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Infrared, Millimeter, and Terahertz waves (IRMMW-THz), 2014 39th International Conference on
  • Conference_Location
    Tucson, AZ
  • Type

    conf

  • DOI
    10.1109/IRMMW-THz.2014.6956190
  • Filename
    6956190