DocumentCode
1530159
Title
Reducing the Axial Spot Size of a Rod-Pinch Diode by a Compound Cathode
Author
Sun, Jianfeng ; Zhang, Pengfei ; Gao, Yi ; Su, Zhaofeng ; Sun, Jiang ; Yang, Hailiang ; Li, YongDong
Author_Institution
Northwest Inst. of Nucl. Technol., Xi´´an, China
Volume
39
Issue
11
fYear
2011
Firstpage
2396
Lastpage
2397
Abstract
The axial spot size of a rod-pinch diode (RPD) has a significant effect on the spatial resolution of the radiographic system, when the RPD is used as an X-ray source for pulsed radiography. The simulation and experiment results indicate that a compound cathode can be used to reduce the axial spot size.
Keywords
cathodes; pinch effect; plasma X-ray sources; plasma diagnostics; plasma diodes; X-ray source; axial spot size; compound cathode; pulsed radiography; radiographic system; rod-pinch diode; spatial resolution; Anodes; Cathodes; Compounds; Electron beams; Plasmas; Radiography; Sun; Axial spot size; compound cathode; particle-in-cell (PIC) simulation; rod-pinch diode (RPD);