DocumentCode
15308
Title
Unprotected Faults of Electrical and Extension Cords in AC and DC Systems
Author
Parise, G. ; Parise, Luigi
Author_Institution
Dept. of Astronaut., Electr. & Energetics Eng., “Sapienza” Univ. of Rome, Rome, Italy
Volume
50
Issue
1
fYear
2014
fDate
Jan.-Feb. 2014
Firstpage
4
Lastpage
9
Abstract
In electrical power systems, all the wiring exposed to mechanical damages and other insulation stresses, such as flexible cords, can be involved in overheating, arcing, and burning. Mechanical damages of the stranded bare conductors can locally degrade the effective sizing of the cross section and cause anomalous local conditions. The circuit protective devices (PDs) can be unfit to detect the faults of cords that remain so energized and available to electric shock and fire hazards. Some fire ignitions result from these types of special unprotected faults. To highlight the local incident energy in case of fault, this paper introduces the parameters steady and transient current densities that assist in analyzing these fault events. Efficient protection can be achieved by the integration of active and passive techniques: adopting arc-fault circuit interrupters or detection devices, recognizing arcing faults, and wiring circuits with a grounding protection conductor to involve the ground in every fault that, in ac systems, is rapidly protected by residual current PDs (or ground-fault PDs). At this aim, the use of special cables, namely, ground-fault-forced cables, is recommended, particularly for cords and extension cords also supplying Class II equipment. The dc system protection requires special care.
Keywords
arcs (electric); cables (electric); conductors (electric); current density; earthing; electric shocks; electrical faults; hazards; residual current devices; AC system protection; DC system protection; arc-fault circuit interrupters; arcing faults; electric shock; electrical cords; extension cords; fire ignition hazards; ground-fault protective devices; ground-fault-forced cables; grounding protection conductor; insulation stresses; requires special care; residual current protective devices; stranded bare conductors; transient current density; Circuit faults; Conductors; Hazards; Ignition; Power cables; Short-circuit currents; Transient analysis; Anomalous overheating; arcing and burning; arcing fault; circuit protection; fire ignition hazard;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.2013.2271605
Filename
6549131
Link To Document