Abstract :
A pair of stationary, opposed scintillation detectors in time coincidence is being used to create planar projection or tomographic images of small animals injected with positron-emitting radiotracers. The detectors are comprised of arrays of individual crystals of Bi12GeO20 coupled to position-sensitive photomultiplier tubes. The system uses FERA (LeCroy Research Systems) charge-sensitive ADCs and a low-cost digital I/O board as a FERA bus-to-host bridge. In projection mode, the animal is placed within the 55 mm×45 mm useful field of view of the detectors, and images are formed from coincidence lines that fall close to the normals of both detectors. In tomographic mode, the animal is placed on a rotation stage between the detectors and rotated around a vertical axis to acquire all possible lines of response. Tomographic images are then reconstructed from those lines falling within a user-specified angle of each detector normal. In mice, the system is capable of high-speed, whole-body dynamic projection imaging, and whole-body tomographic imaging of slowly varying tracer distributions. An ECG gating capability is also available for evaluating cardiac function. This system is currently being used to study tracer transport in normal and genetically engineered mice
Keywords :
analogue-digital conversion; electrocardiography; genetics; image processing equipment; image reconstruction; photomultipliers; positron emission tomography; radioactive tracers; scintillation counters; zoology; Bi12GeO20; ECG gating capability; FERA bus-to-host bridge; FERA charge-sensitive ADC; PET/planar small-animal imaging system; cardiac function evaluation; coincidence lines; crystal arrays; field of view; genetically engineered mice; high-speed whole-body dynamic projection imaging; low-cost digital I/O board; planar projection images; position-sensitive photomultiplier tubes; positron-emitting radiotracers; projection mode; rotation stage; slowly varying tracer distributions; stationary opposed scintillation detectors; time coincidence; tomographic image reconstruction; tomographic mode; tracer transport; user-specified angle; whole-body tomographic imaging; Animals; Bismuth; Crystals; Mice; Photomultipliers; Position sensitive particle detectors; Positron emission tomography; Scintillation counters; Sensor arrays; Solid scintillation detectors;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.775581
Filename :
775581
Link To Document :
بازگشت