DocumentCode
1531755
Title
A method for the analysis and control of mica tape impregnation processes
Author
Velten, K. ; Zemitis, A. ; Pfreundt, F.-J. ; Hennig, E. ; Schattauer, D.
Author_Institution
Inst. of Ind. & Economath., Kaiserslautern, Germany
Volume
6
Issue
3
fYear
1999
fDate
6/1/1999 12:00:00 AM
Firstpage
363
Lastpage
369
Abstract
The impregnation of mica tape insulations usually is monitored with dielectric capacitance measurements. In this work, a method is developed that translates measured capacitance and loss into an average drag coefficient that characterizes flow resistance, which is the critical parameter of the process. In a first step, the impregnation depth is determined based on an appropriate model of the dielectric measurement. The impregnation depth curve and its derivative are then used to compute the average drag coefficient, which is defined in the framework of a standard porous media flow model. The method has been developed and tested for cylindrical insulators. Appropriate extensions to rectangular insulators are indicated
Keywords
capacitance; impregnated insulation; machine insulation; mica; average drag coefficient; cylindrical insulators; dielectric capacitance measurements; flow resistance; impregnation depth; mica tape impregnation processes; mica tape insulation; rectangular insulators; standard porous media flow model; Capacitance measurement; Dielectric loss measurement; Dielectric measurements; Dielectrics and electrical insulation; Drag; Electrical resistance measurement; Fluid flow measurement; Insulator testing; Loss measurement; Monitoring;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/94.775624
Filename
775624
Link To Document