Title :
Microcomputer-based signal processor for short range FM radar
Author :
Delauder, D.M. ; Balanis, Constantine A. ; Kazovsky, Leonid G.
Author_Institution :
Litton Amecon, College Park, MD, USA
fDate :
3/1/1986 12:00:00 AM
Abstract :
The design and testing of a microcomputer-based data acquisition and range display instrument for use with FM radar systems are described. The system was particularly designed to measure targets at close range (two meters or less). The instrument has been applied to the problem of measuring the bed level within a fluidized-bed combustion chamber. Results of the experiments indicate that for monitoring static targets, an average error of 2-4% can be expected. For the more demanding case of dynamic targets, the accuracy is reduced slightly, with errors on the order of 4%; at the same time, subjectivity is significantly increased.
Keywords :
combustion; computerised signal processing; data acquisition; fluidised beds; frequency modulation; level measurement; microcomputer applications; radar applications; radar displays; radar systems; signal processing equipment; telecommunications computing; bed level; computerised signal processing; dynamic targets; fluidized-bed combustion chamber; microcomputer-based data acquisition; monitoring static targets; range display instrument; short range FM radar;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
DOI :
10.1109/TIM.1986.6499060