Title :
Energy-based adaptive focusing of waves: application to noninvasive aberration correction of ultrasonic wavefields
Author :
Herbert, E. ; Pernot, M. ; Montaldo, G. ; Fink, M. ; Tanter, M.
Author_Institution :
Inst. Langevin, ESPCI ParisTech., Paris, France
Abstract :
An aberration correction method based on the maximization of the wave intensity at the focus of an emitting array is presented. The potential of this new adaptive focusing technique is investigated for ultrasonic focusing in biological tissues. The acoustic intensity is maximized noninvasively through direct measurement or indirect estimation of the beam energy at the focus for a series of spatially coded emissions. For ultrasonic waves, the acoustic energy at the desired focus can be indirectly estimated from the local displacements induced in tissues by the ultrasonic radiation force of the beam. Based on the measurement of these displacements, this method allows determination of the precise estimation of the phase and amplitude aberrations, and consequently the correction of aberrations along the beam travel path. The proof of concept is first performed experimentally using a large therapeutic array with strong electronic phase aberrations (up to 2pi). Displacements induced by the ultrasonic radiation force at the desired focus are indirectly estimated using the time shift of backscattered echoes recorded on the array. The phase estimation is deduced accurately using a direct inversion algorithm which reduces the standard deviation of the phase distribution from sigma = 1.89 radian before correction to sigma = 0.53 radian following correction. The corrected beam focusing quality is verified using a needle hydrophone. The peak intensity obtained through the aberrator is found to be -7.69 dB below the reference intensity obtained without any aberration. Using the phase correction, a sharp focus is restored through the aberrator with a relative peak intensity of -0.89 dB. The technique is tested experimentally using a linear transmit/receive array through a real aberrating layer. The array is used to automatically correct its beam quality, as it both generates the radiation force with coded excitations and indirectly estimates the acoustic intensity at the focus wi- h speckle tracking. This technique could have important implications in the field of high-intensity focused ultrasound even in complex configurations such as transcranial, transcostal, or deep seated organs.
Keywords :
acoustic field; biological tissues; biomedical transducers; biomedical ultrasonics; nonlinear acoustics; ultrasonic focusing; ultrasonic therapy; ultrasonic transducer arrays; aberrator; acoustic energy; beam quality; beam travel path; biological tissues; diagnostic imaging array; direct inversion algorithm; energy-based adaptive focusing technique; linear transmit-receive array; needle hydrophone; noninvasive aberration correction method; phase correction; phase distribution; phase estimation; therapeutic array; ultrasonic focusing; ultrasonic radiation force; ultrasonic wavefields; wave intensity maximization; Acoustic beams; Acoustic emission; Acoustic measurements; Acoustic waves; Biological tissues; Displacement measurement; Energy measurement; Phase estimation; Phased arrays; Ultrasonic variables measurement; Artifacts; Computer-Aided Design; Equipment Design; Equipment Failure Analysis; Image Enhancement; Reproducibility of Results; Sensitivity and Specificity; Ultrasonography;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :
10.1109/TUFFc.2009.1327