Title :
Multi-end correlation-based PD location technique for medium voltage covered-conductor lines
Author :
Isa, Muzamir ; Elkalashy, Nagy I. ; Lehtonen, Matti ; Hashmi, Ghulam M. ; Elmusrati, Mohammed S.
Author_Institution :
Dept. of Electr. Eng., Aalto Univ., Espoo, Finland
fDate :
6/1/2012 12:00:00 AM
Abstract :
In Finland, overhead covered conductors (CC) are commonly used in the medium voltage (MV) networks because the distribution loads in rural areas are not heavy and are widely distributed in the forested terrain. Such parts of the network are exposed to leaning trees and therefore partial discharging into the overhead CC frequently occurs. In this paper, a multi-end correlation-based technique for locating partial discharge (PD) sources on CC lines is presented. The theory of maximum correlation factor is used in order to find the time differences between signal arrivals at three synchronized-measuring points. This helps to solve the problem of varying parameters of the CC line that can change the propagation velocity and the problem of identifying the arrival times of the corresponding PD pulses at different measuring points. The algorithm is developed and tested using a simulated study and experimentally verified using an alternating current (ac) energized system. The Electromagnetic Transient Program-Alternative Transient Program (EMTP-ATP) is used to implement and analyze a PD monitoring system. The Discrete Wavelet Transform (DWT) is used to de-noise PD signals measured from a Rogowski coil utilized as a high frequency transducer. The noise model is added to the simulated-power network signals and then a DWT-based de-noising process is carried out. The proposed algorithm performance is evaluated by extracting the high frequency features using a windowed-standard deviation. The simulated and experimental evaluations prove that accurate PD source location can be achieved using the proposed algorithm technique.
Keywords :
EMTP; computerised monitoring; discrete wavelet transforms; feature extraction; overhead line conductors; partial discharges; signal denoising; AC energized system; DWT; DWT-based denoising process; EMTP-ATP; Finland; MV networks; PD monitoring system; PD pulses; PD signal denoising; PD source location; Rogowski coil; alternating current energized system; discrete wavelet transform; distribution loads; electromagnetic transient program-alternative transient program; forested terrain; high frequency feature extraction; high frequency transducer; leaning trees; locating PD sources; locating partial discharge sources; medium voltage covered-conductor lines; medium voltage networks; multiend correlation-based PD location technique; overhead CC lines; propagation velocity; rural areas; signal arrivals; simulated-power network signals; synchronized-measuring points; windowed-standard deviation; Coils; Correlation; Discrete wavelet transforms; Noise; Partial discharges; Synchronization; Correlation; EMTP-ATP; Rogowski coil; distribution systems; overhead covered-conductor; partial discharge; wavelet transforms;
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
DOI :
10.1109/TDEI.2012.6215097