DocumentCode
1539507
Title
High-frequency voltage stress of insulation. Methods of testing
Author
Pfeiffer, W.
Author_Institution
Tech. Hochschule, Darmstadt, Germany
Volume
26
Issue
2
fYear
1991
fDate
4/1/1991 12:00:00 AM
Firstpage
239
Lastpage
246
Abstract
Traditionally high electrical stress of insulation occurs in HV equipment. Usually this stress is 50/60 Hz AC and rather seldom DC. Exceptional situations may occur in RF transmitters. This is very different in low voltage equipment. Due to the increased use of high-power semiconductors with high cutoff frequency, working voltages of rather high amplitudes and with frequencies >100 kHz occur frequently. Also, the distances through solid insulation may be rather low resulting in electrical fields in excess of those being typical for HV equipment. In combination with such HF working voltages, this means an extraordinary stress for the insulation. As there is a strong economical interest in further miniaturization, those problems have to be analyzed more precisely. The most important data about HF stress of insulation are summarized in this paper
Keywords
insulating materials; insulation testing; materials testing; HF stress; HV equipment; RF transmitters; high cutoff frequency; high electrical stress; high-power semiconductors; solid insulation; voltage stress; Breakdown voltage; Dielectrics and electrical insulation; Electric breakdown; Frequency; Hafnium; Insulation testing; Low voltage; Radio transmitters; Solids; Stress;
fLanguage
English
Journal_Title
Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
0018-9367
Type
jour
DOI
10.1109/14.78324
Filename
78324
Link To Document